- Based on RIGOL's brand new self-developed Centaurus technical platform
- 12-bit resolution for all the series[1]
- Max. 1 GHz bandwidth, 8 analog channels, and 1 external trigger channel
- Standard configuration of 16 digital channels (required to purchase the logic analyzer probe) for the MHO models
- Real-time sample rate : up to 4 GSa/s
- Max. memory depth 500 Mpts
- Vertical sensitivity up to 100 μV/div
- Maximum waveform capture rate of 1,000,000 wfms/s in fast recording mode
- Arbitrary Waveform/Function Generator (AFG)[2], power analysis, histogram, and digital signal analysis[3], Bode plot[4], and protocol decodings
- Search and navigation functions enable users to quickly search for the signals with exceptions and locate them accurately
- 256-level intensity grading display, with digital real-time fluorescence technology
- 10.1" 1280x800 high-definition touch screen
- Brand new Flex knob brings friendly user experience
- Standard configuration of USB Device, USB Host, LAN, HDMI interfaces for all the series
- Battery pack-powered, convenient to charge anytime and anywhere, providing great feasibility for measurement
- Online upgrade
- Standard configuration of the photoelectric encoder operating knob for all the series to improve the service life of the instrument
Specifications
|
DHO5000 Series |
||||
|
Model |
DHO5058 |
DHO5054 |
DHO5108 |
DHO5104 |
|
Analog Bandwidth (50 Ω, -3 dB) |
500 MHz |
1 GHz |
||
|
Analog Bandwidth (1 MΩ, -3 dB) |
500 MHz |
|||
|
Calculated Rising Time under 50 Ω (10%-90%, Typical) |
750 ps |
750 ps |
400 ps (single-channel[1]& half-channel[2]) 440 ps (full-channel[3]) |
400 ps |
|
No. of Input Channels |
DHO5058/DHO5108: 8 analog channels + 1 EXT channel DHO5054/DHO5104: 4 analog channels + 1 EXT channel |
|||
|
Max. Sample Rate of Analog Channel |
DHO5058/DHO5108 : 4 GSa/s (single-channel[1] & half-channel[2]), 2 GSa/s (full-channel[3]) DHO5054/DHO5104 : 4 GSa/s (single-channel[1] & half-channel[2] & full-channel[3]) |
|||
|
MHO5000 Series |
||||
|
Model |
MHO5056 |
MHO5054 |
MHO5106 |
MHO5104 |
|
Analog Bandwidth (50 Ω, -3 dB) |
500 MHz |
1 GHz |
||
|
Analog Bandwidth (1 MΩ, -3 dB) |
500 MHz |
|||
|
Calculated Rising Time under 50 Ω (10%-90%, typical) |
750 ps |
750 ps |
≤400 ps (single-channel[1] &half-channel[2]) ≤440 ps (full-channel[3]) |
|
|
No. of Input Channels |
MHO5054/MHO5104: 4 analog channels + 1 EXT channel + 16 digital channels MHO5056/MHO5106: 6 analog channels + 1 EXT channel + 16 digital channels
Note : The logic analyzer probe is required to be purchased to work with the digital channel. |
|||
|
Max. Sample Rate of Analog Channel |
4 GSa/s (single-channel[1] &half-channel[2]), 2 GSa/s (full-channel[3]) |
|||